Bilirubin, Pediatric, Plasma

BC0094

Synonym(s):
Specimen Container
Tubes containing lithium heparin as anti-coagulant
Specimen Requirement

200uL whole blood.


Please ensure proper blood collection and sealing of the microvette tube [click here for guide for collection].


Invert blood 5 times after blood collection ensures the anticoagulant is well mixed with the blood. This will ensure results are reliable.

Orderable as Urgent? Yes
Turn Around Time
Urgent: 1 hour
Routine: Average 2 hrs (1 - 3 hrs)
Reference Value(s)

 

Age

Reference Range (µmol/L)

Female

Male

0 - <1 day

<103

1 day - <3 days

<171

3 days - <6 days

<205

6 days - <30 days

0 - 100

≥30 days

3 - 21


Testing Laboratory Location KKH
Laboratory Clinical Chemistry
Contact Number 6394 1383
Day and Time Performed
Daily, 24 hrs
Orderable on CPOE? Yes
Downtime Form

Clinical Chemistry - Form A

Additional Information
Critical Value: -High: >300 µmol/L

Change History Notes

  • 20 Jan 2025 11:00 AM

    Updated Turn around Time.

  • 12 Jul 2024 11:00 AM

    ​Updated Reference Value(s).

  • 19 Oct 2021 01:50 PM

    Updated Specimen Container and Specimen Requirement.

Back: eLab Book (Test Catalogue)

Last Updated - 21 Jun 2025